Online UPS(3ph) 10KVA-200KVA,0.9/1.0 Output Power Factor
工频在线UPS
Applications
IDC room, Large and medium computer networks, Banks, Securities, Communication centers, Semiconductor production lines, Large-scale automated production and control systems, Large gymnasium, Conference rooms, Theaters, Highways, Railways, Tunnels and lighting systems.
Input voltage: 380Vac,384Vac,415Vac,480Vac,528Vac/3phases;
Output voltage: 220Vac,230Vac,240Vac,380Vac,384Vac,415Vac/3phases available
Battery voltage: 125Vdc,216Vdc,220Vdc, 380Vdc,384Vdc, 432Vdc, 480Vdc available; Batteries can be with lead acid batteries or nickel cadmium batteries
Introduction
Online
UPS provides maximum protection for vital mission-critical networks,
security applications (electro-medical) and industrial applications
thanks to its outstanding mechanical and electrical design.The load is
powered continuously by the inverter with a filtered, stabilised and
regulated sinewave supply. The input and output EMI filters considerably
increase the immunity of the load to mains disturbances and surges.
The
UPS uses on-line double conversion technology (VFI) with and isolation
transformer on the inverter output.UPS is supplied with Watch & Save
3000 software as standard and can be remotely monitored using the Power
NetGuard system from anywhere in the world. Additional battery
extension packs allow the standard battery runtime to be extended up to
several hours
Features
●Minimum impact on supplies easy sourse
Input current distortion <4% for the UPS with filter with sinusoidal absorption to remove the risk of
resonance
with other input supply users or phase shift capacitor sets. The
absorbed current distortion is independent of input supply parameters
such as impedance. This enable UPS to deliver maximum performance levels
regardless of the installation environment. With these input features
UPS can achieve significant savings in terms of sizing and power supply
sources-isolation transformers and generators over less sophisticated
power systems.
●Maxmum battery care
Battery deep discharge protection; Temperature compensating charger; Built-in automatic and manual battery test feature
●Simple to install
Capability
to install the UPS into any distribution system (neutral not required
on rectifier input);Capability to separate the rectifier/bypass power
networks and to power these from two separate sources, without Galvanic
isolation (Necessary on UPS without an output transformer).
●High reliability
Extremely
high short-circuit current to ensure compatibility with the most
difficult transformer applications (lighting,drives and industrial
processes) and an isolation transformer on the inverter output;
●Full microprocessor control with no-break static and manual bypasses;
●IGBT technology.
●High
level diagnostics: event lo with 128 messages, states,measurements and
alarms available from the built-in LCD in several languages;
●BACK FEED protection: to avoid energy feeding back into the mains supply should a fault occur.
●Connect
up to 8 units in parallel or N+1 redundancy, even of different power
ratings.The UPS continue to work in parallel even if one of the
interconnecting communication cables is disconnected (CLOOSED LOOP).
●Low consumption levels
UPS
can achieve efficiencies >98% thanks to selectable Economy Mode
which can be used in stable electrical environments to provide power
supply continuity should the mains fail.
●Advance communication
● Compatible with TeleNetGuard for remote maintenance;
●
Advanced, multi-platform communication for all operation systems and
network environments: Watch & Save 3000 monitoring and shut-down
software included, with SNMP agent, for Windows 2008, ista,2003, XP; Mac
OS X,Linux, Novell and most popular Unix operating systems
● The UPS is supplied with a cable for direct connection to the PC(Plug and Play);
● RS232 or RS485 double Serial port;
● Installation slot for an Emergency Power Off (EPO) interface to allow the UPS to be switched off remotely in an emergency;
●
Generator interface: enables desynchronisation of the UPS output from a
generator supply which may be subject to phase and frequency
variations. The interface also enables more economic use of the battery
charge
Specification
Model | GS9331C 10KVA-200KVA | |||||||||
Capacity | 10KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 160KVA | 200KVA |
10KW | 20KW | 30KW | 40KW | 60KW | 80KW | 100KW | 120KW | 160KW | 200KW | |
Input | ||||||||||
Voltage | 380/400/415/432/480/528VAC;3-phase+4wires | |||||||||
Voltage range | 380VAC±25% | |||||||||
Frequency | 50/60HZ | |||||||||
Frequency range | ±5% | |||||||||
THDi | <3% | |||||||||
Power factor | >0.9 | |||||||||
Bypass voltage | 380/400/415VAC;3-phase+4wires | |||||||||
Input frequency | 50/60HZ±10% | |||||||||
Output | ||||||||||
Voltage | 220/230/240/380/400/415VAC;3-phase+4wires | |||||||||
Voltage stability | ±1% stead status | |||||||||
Frequency | 50/60Hz±0.05Hz | |||||||||
Power factor | 0.9 or 1.0 | |||||||||
Overload | ≤110%for 60 minutes;≤125% for 10min;≤150% for 1min | |||||||||
Current Crest Ratio | 3:1 | |||||||||
Transfer time | 0 ms | |||||||||
Battery | ||||||||||
DC voltage | 110V/125VDC/216VDC/360VDC/384VDC/432VDC/480VDC,VRLA,NiCd battery | |||||||||
Charge time | 8 hours to 90% (it means standard model which battery inside UPS) | |||||||||
DC ripple voltage | <1% | |||||||||
LCD display | UPS status, input/output voltage and frequency,battery voltage, capacity,load temperature,history records,adjust Voltage,ECO mode | |||||||||
Communication | RS232, AS400,RS485,SNMP (Optional),USB(Optional) | |||||||||
Efficiency | >98% | |||||||||
Protection | IP21 | |||||||||
Working temperature | 0~40°C | |||||||||
Humidity | 0~95% non-condensing | |||||||||
Storage temperature | -25°C~70°C | |||||||||
Elevation | 1000M | |||||||||
Noise | <45dB | |||||||||
Dimension(mm) | 550x720x1200 | 800x740x1400 | 1050x740x1400 | |||||||
Weight(kgs) | 190 | 210 | 290 | 340 | 440 | 520 | 770 | 855 |