Frequency Converter (380V or 400V or 10KV ) 60KVA-400KVA
Greencisco 50Hz/60Hz/400Hz variable-frequency converter power is a power equipment widely used for Airplane,Radar,Navigation,Navy,Port,Shipyard,Shiprepair,Shipbuilding,Dockyard,Testing,ect.
Introduction
Shore frequency converters are specially used in ports, dockyard fitting-out berth, ships and ocean drilling platforms with outdoor harsh environments which need outdoor frequency conversion variables with high reliability of power supply. This series of products adopt full sealed three layers of insulation pipeline with full air conditioning circulation protection. Inside of equipment environment is completely isolation with the outside world. Equipment tank protection level IP66, air conditioning system is level IP56, fully meet the shore wharf, ships and drilling platforms with any harsh outdoor environments. A complete set of equipment in accordance with the standard container box shape design, easy to transport and move often.
Feature
●Using the full sealed air conditioning cooling system with three insulation layer tank to ensure that the equipment is under good protection.
●Adopting the latest instantaneous voltage waveform control technology, output voltage fluctuation≤0.5V,when 100% load, the output voltage fluctuation less than 3% and recover to the rated output voltage value in 0.5 wave cycle.
●Adopting technology of pure sine inverter output filter. Reduce the output impedance of the sinusoidal filter and improve the quality of the output power.
●Driven by our module with signal master-slave synchronization parallel technology. Which can realize parallel working of many shore variable power equipments without current circulation interference.
●Using the power switching devices which is made by Germany, DSP core is made by USA with 5Mhz optical fiber driver transmission mode. The inverter modulation method adopts the latest SVPWM space vector pulse width modulation.
Specification
Model | SFC-60 | SFC-100 | SFC-120 | SFC-150 | SFC-200 | SFC-250 | SFC-300 | SFC-350 | SFC-400 |
Capacity(KVA) | 60 | 100 | 120 | 150 | 200 | 250 | 300 | 350 | 400 |
Input Voltage | 400VAC±10%/10KV±10%,3phases,can be customized special voltage input according to customers'requirements | ||||||||
Frequency | 50Hz±10%/60Hz±10% | ||||||||
Phase | 3phases+3wires or 3phases+5 wires | ||||||||
Rectifier | 6pluses or PWM | ||||||||
Power factor | 6pluses>0.95; PWM>0.99 | ||||||||
THDi | <35%(6pluses at 100%load)or<5% (PWM at 100% load) | ||||||||
Output Voltage | 440VAC, 6.6KV (can be customized special voltage output) | ||||||||
Capacity | 60KVA | 100KVA | 120KVA | 150KVA | 200KVA | 250KVA | 300KVA | 350KVA | 400KVA |
Phase | 3phases+3wires or 3phases+4wires | ||||||||
Voltage Stabilizing | <0.5V at static; <±1%(dynamic,0-100%load) | ||||||||
Frequency | 50Hz or 60Hz (precision:0.01) | ||||||||
Frequency stabilizing | <0.01%(0-100%load) | ||||||||
Overload ability | 125% for 1minute; 150% stop output;can withstand 3 times of instant impact | ||||||||
Total harmonic distortion of output voltage THDu | ≤1%(no load or line load ) | ||||||||
Peak coefficient of output voltage CF | 1.4+0.1(No load) | ||||||||
Three phase output voltage imbalance | <1% | ||||||||
Phase angle of three-phase output voltage | 120°(±0.1°) | ||||||||
Efficiency | ≥95%(100%load) | ||||||||
Inverter main circuit topology | IGBT modules constitutes a three-phase full-bridge inverter circuit | ||||||||
Inverter adjustment method | SVPWM space vector pulse width modulation method | ||||||||
Voltage stabilizing control | Instantaneous voltage waveform feedback control method | ||||||||
Inverter switch frequency | 3.6KHZ~6KHZ | ||||||||
PWM Drive Transmission Mode | 5MHZ fiber drive transmission | ||||||||
Master processor | 150NHz | ||||||||
Sinusoidal filtering method | Three-stage sinusoidal filter at output of inverter | ||||||||
Display | LCD display or digital display | ||||||||
Compressive strength | Low pressure: 2500V/AC, 1 minute, no breakdown fire phenomenon(leakage current 10mA); High Pressure: 42 KV/AC, 1 minute, should not break through the fire phenomenon | ||||||||
Cold insulation resistance | ≥100MΩ | ||||||||
Noise | ≤55dB(A) | ||||||||
Environment | Ambient temperature is -5 °C to +45 °C, and the relative humidity is 0 to 95 °C,Working for 24 hours at 100% full load,the temperature in the equipment cabin is in the range of 25 °C ± 1 °C | ||||||||
Protection Class | IP32 | ||||||||
Cooling | forced fan | ||||||||
Elevation | <1000M | ||||||||
Software Application Macro | Selection of marine shore frequency converter application macros, analog power grid application macros, inverter test macros, electric motor macros and ex-factory test macros and transformer test macros | ||||||||
Protection | Phase deficit(three-phase imbalance), undervoltage, overvoltage, overcurrent, short circuit, DC bus overvoltage, frequency power supply trip protection. (protection threshold can be set) | ||||||||
Dimension(LXWXH)mm | 800x650x1800 | 1100x1000x2000 | 2000x1200x2200 | 2900x1500x2200 | |||||
Weight(KGS) | 400 | 900 | 1000 | 1200 | 1300 | 1500 | 1800 | 2000 | 2100 |