欢迎访问格林思科实业有限公司官方网站

270Vdc Power for military

Widely used for aircraft, radar,airplanes, airports, airplane analog testing,Aerospace,trucks and shipyards,airborne equipment,navigation and other military electronic equipments.ect.

产品详情

Introduction
Adopted PWM control and IPM converter technology, with fast response speed, high overcurrent ability, low output ripple.
With features of small size, light weight, low noise, high efficiency,ect.
Widely used for aircraft, radar,airplanes, airports, airplane analog testing,Aerospace,trucks and shipyards,airborne equipment,navigation and other military electronic equipments.ect.
Meet standards of MIL-STD-704,GJB181A-2003 aircraft power supply characteristics
Meet GJB 572-88 aircraft ground power supply characteristics and general requirements
Meet MH/T6018-1999 static ground power supply
Meet GJB151A-1997 Electromagnetic emission and sensitivity requirements for military equipment and subsystems
Meet GB/T3859.1-1993 Specification for basic requirements for semiconductor convertors

Specification

Model

PDC-270/10

PDC-270/30

PDC-270/50

PDC-270/100

PDC-270/150

PDC-270/200

PDC-270/300

Capacity

2.7KW

8.1KW

13.5KW

27KW

40.5KW

54KW

81KW

Circuit mode

Silicon controlled mode

AC Input


Phase

3 phases+4 wires+ground

Voltage

380VAC/220VAC±10%

Frequency

50Hz/60Hz±3Hz

DC Output


Voltage

270Vdc±10% (230Vdc-310Vdc adjustable)

Current

10A

30A

50A

100A

150A

200A

300A

Overload

150% for 10 seconds

Voltage
stability

<0.5%

Load
stability

<0.5%

Vrms

<1%

Display

LED & digital display

Protection

Overvoltage, overcurrent, overtemperature, shortcircuit protection

Cooling

Forced fan

Temperature

20℃<0<45℃,0-90% No Condensation

Insulation

>10MΩ at 500Vdc

Voltage
insulation

At 1500Vac for 1 minute, no arc

Noise

<65db

Efficiency

>85%

Communication

RS232/RS485/Relay (optional)

Application

For airport use, it will be with 10M cables+Airport connector+trolley

Model

PDC-270/500

PDC-270/600

PDC-270/1000

PDC-270/1200

PDC-270/1500

PDC-270/1800

PDC-270/2000

Capacity

135KW

162KW

270KW

324KW

405KW

486KW

540KW

Circuit mode

Silicon controlled mode

AC Input


Phase

3 phases+4 wires+ground

Voltage

380VAC/220VAC±10%

Frequency

50Hz/60Hz±3Hz

DC Output


Voltage

270Vdc±10% (230Vdc-310Vdc adjustable)

Current

500A

600A

1000A

1200A

1500A

1800A

2000A

Overload

150% for 10 seconds

Voltage
stability

<0.5%

Load
stability

<0.5%

Vrms

<1%

Display

LED & digital display

Protection

Overvoltage, overcurrent, overtemperature, shortcircuit protection

Cooling

Forced fan

Temperature

20℃<0<45℃,0-90% No Condensation

Insulation

>10MΩ at 500Vdc

Voltage
insulation

At 1500Vac for 1 minute, no arc

Noise

<65db

Efficiency

>85%

Communication

RS232/RS485/Relay (optional)

Application

For airport use, it will be with 10M cables+Airport connector+trolley