Solar hybrid inverters
Widely used for solar power system,home use,offices,computers,TV,mobiles,ect.
Application:
Widely used for solar power system,home use,offices,computers,TV,mobiles,ect.
Features:
Pure sine wave output
Cold start function
Auto restart while AC is recovering
Programmable supply in priority for PV, battery or AC grid and multiple modes of offgrid mode, grid-tie mode with battery and AC grid mode
Adjustable charging current and voltage
Monitoring function for real-time status display and control
Can be parallel together with 9 units
Selectable input voltage range for home appliances and personal computers
Specification:
Model | Gpower-2KW | Gpower-3KW | Gpower-5KW | Gpower-10KW | Gpower-15KW |
PV array power | 2.2KW | 4.5KW | 10KW | 15KW | 22KW |
Rated output power | 2KW | 3KW | 5KW | 10KW | 15KW |
Grid-tie mode | |||||
Normal PV input voltage | 300VDC | 360VDC | 720VDC | 720VDC | 720VDC |
PV starting voltage | 80VDC | 116VDC | 225VDC | 320VDC | 320VDC |
Max PV voltage | 120VDC-320VDC | 250VDC-450VDC | 250VDC-850VDC | 400VDC-800VDC | 400VDC-800VDC |
MPPT tracker number | 1 | 1 | 2 | 2 | 2 |
Max PV input current | 15A | 18A | 2x10A | 2x18A | 2x18A |
Grid AC output | |||||
Rated output voltage | 110/120VAC | 208/220/230/240VAC | 380/400VAC | ||
Output voltage range | 88-127VAC | 184-265VAC | 320-458VAC | ||
Rated output current | 18A | 13A | 21A | 25A | 37.5A |
Power factor | >0.99 | ||||
Efficiency | |||||
Max conversion efficiency | 96% | ||||
Offgrid,Hybrid mode | |||||
AC input | 110/120VAC | 220/230/240VAC | 380/400VAC | ||
Input voltage range | 80-130VAC | 170-280VAC | 295-480VAC | ||
Frequency range | 50Hz/60Hz | ||||
Max AC input current | 30A | 40A | 40A | 40A | 40A |
PV DC input | |||||
Max DC input voltage | 350VDC | 500VDC | 900VDC | 900VDC | 900VDC |
MPPT voltage range | 150VDC-320VDC | 250VDC-450VDC | 250VDC-850VDC | 400VDC-800VDC | 350VDC-850VDC |
MPPT tracker number | 1 | 1 | 2 | 2 | 2 |
Max PV input current | 18A | 18A | 2x10A | 2x18A | 2x18A |
Battery AC output mode | |||||
Rated output voltage | 110/120VAC | 220/230/240VAC | 380/400VAC | ||
Output waveform | Pure sine wave | ||||
DC to AC efficiency | 93% | 93% | 93% | 93% | 93% |
Hybrid mode | |||||
Rated PV DC input voltage | 300VDC | 360VDC | 720VDC | 720VDC | 720VDC |
Max DC input voltage | 350VDC | 500VDC | 900VDC | 900VDC | 900VDC |
PV starting voltage | 80VDC | 115VDC | 225VDC | 320VDC | 320VDC |
MPPT voltage range | 150VDC-320VDC | 250VDC-450VDC | 250VDC-850VDC | 400VDC-800VDC | 350VDC-850VDC |
MPPT tracker number | 1 | 1 | 2 | 2 | 2 |
Max PV input current | 18A | 18A | 2x10A | 2x18A | 2x18A |
AC input | |||||
Rated input voltage | 110/120VAC | 220/230/240VAC | 380/400VAC | ||
Input voltage range | 80-130VAC | 170-280VAC | 295-480VAC | ||
Max AC input current | 30A | 40A | 40A | 40A | 40A |
AC output | |||||
Rated output voltage | 110/120VAC | 220/230/240VAC | 380/400VAC | ||
Output waveform | Pure sine wave | ||||
AC output current | 18A | 13A | 21A | 25A | 37.5A |
Battery AC output mode | |||||
Rated output voltage | 110/120VAC | 220/230/240VAC | 380/400VAC | ||
Output waveform | Pure sine wave | ||||
DC to AC efficiency | 93% | 93% | 93% | 93% | 93% |
Battery and charger | |||||
Rated DC voltage | 48VDC | 48VDC | 48VDC | 48VDC | 48VDC |
Max charge current | 25A | 60A | 100A | 200A | 300A |
Dimension(DxWxH)mm | 100x440x480 | 100x440x480 | 200x460x600 | 168x500x625 | 220x650x800 |
Weight(KGS) | 15 | 15 | 30 | 40 | 60 |
Communication | RS232/RS485/USB/SNMP | ||||
Humidity | 0 to 90% RH (non-condensing) | ||||
Operation temperature | 0 to 50°C | ||||
Storage temperature | (-)15°C to 60°C |