Greencisco Industrial Co., Ltd.

GRLFP-384V150AH lithium battery

We provide safety solutions with our LiFePO4 batteries for UPS, solar energy storage system, telecom stations, ect.,which are with perfect compatibility and safe long cycle life.

Characteristics

Introduction

We provide safety solutions with our LiFePO4 batteries for UPS, solar energy storage system, telecom stations, ect.,which are with perfect compatibility and safe long cycle life.

Features

Automatic circulation control and easy to realize parallel machines use

High precision cell voltage and temperature: ±3mv,±1

The maximum internal cell equalization current upto 200mA

Fire extinguision device in the module for 7 days/24hours protection

With IBB integrated bus design in the module to realize the cell strings without screws and cables

With full status management and 100% real-time cell management and control

With high-precision leakage detection to prevent insulation failure and ensure system reliability.

With high energy efficiency>98%

With multiple protections of overcharge, overdischarge and short-circuit protections, overtemperature, ect.

With LCD display and RS485 communication, ect.

Specification

Model

GRLFP-384V150AH

Electrical

Parameters

(25°C)

Rated Voltage

384V

Rated Capacity (C5)

150Ah@25°C

Energy

57600Wh

Months Self Discharge

<3%

Charge Efficiency

99.5%@ 0.2C

Discharge Efficiency

96-99%@ 1C

Terminal Diameter

M8

Internal resistance (Fully charged, 25°C)

≤280mΩ

Cycle life

>4000 cycles @ 0.2C 100%D.O.D

Capacity

affected by

temperature

40°C

101%

25°C

100%

0°C

90%

-10°C

75%

Nominal operating temperature

25°C± 3°C (77°F± 5°F)

Operating

temperature

range

Discharge

- 20°C~ 60°C (-4°F ~ 140°F)

Charge

0°C~ 45°C (32°F ~ 113°F)

Storage

0°C~ 40°C (32°F ~ 104°F)

Water Dust Resistance

IP50

Charge Voltage

420V

Standard Charge Mode

(25°C±2°C, <75%RH)

0.2CA Constant Current to 420V,

then Constant Voltage 420V

until the current drops to 0.02CA,

before use, rest 30 minutes

Charge Current

30A

Maximum Charge Current

75A

Charge Cut off Voltage

420V

Continuous Discharge Current

150A

Maximum Pulse Current

250A (<2S, Adjustable)

Discharge Cut Off Voltage

360V

Communicate Protocol (optional)

RS485/RS232/CAN

SOC (optional)

Screen/LED/PC Software

Application connection

1 string 1 parallel

Mechanical

Cells Qty

120 Strings

Length

1000±2mm (39.37inch)

Width

730±2mm (28.74inch)

Height

1080±2mm (42.52inch)

Weight

559.0kg (1232.37lbs)±20kg

Container

Metal